For More Information and Test to Standards on the following labs, download the .pdf copy by clicking here.

 

NATIONAL CENTRE FOR SUPERVISION & INSPECTION OF DRAINAGE IRRIGATION & WASTE
NO. 33 TIANDU ROAD,
HEFEI ECONOMIC & TECHNICAL
DEVELOPMENT ZONE,
HEFEI, ANHUI, -- 230601
CHINA
Contact: CHENG XIAOMIN (SMITHY)

Phone: +86-551-713-2010
Fax: +86-551-713-2020
   Lab #: 0000088
Expires: 8/31/2019
Number of Employees: 20

Tests to Standards:
Appliances:
ANSI/ AHAM DW-1-2010 (Section 7 only)

Ballcocks/Flushometers:
ATS 5200.016-2005, ATS 5200.017-2005, ASSE 1002-2015/ASME A112.1002-2015/ CSA B125.12-15,ASME A112.19.5-2017/ CSA B125.15-17, ASSE 1037-2015/ASME A112.1037-2015/ CSA B125.37-2015

Electrical:
IGC 314-15e

Low Lead:
NSF/ ANSI 372-2016, AB 1953/ Section 1417(d) of the Safe Drinking Water Act

Metal Fixtures:
ASME A112.19.3-2017/CSA B45.4-17, CSA B45-08, CSA B79-2008 (R2013), IAPMO PS 117-2017

Metal Pipe\Fittings:
ASTM A888-2008, ASTM C1277-2006, ASME A112.18.2-2015/CSA B125.2-15, ASSE 1061-2011, ASME B16.22-2013, ASME A112.6.3-2016

Nonmetallic Pipe\Fittings:
ASME A112.18.6-2017/ CSA B125.6-17, AS/NZS 3499:2006, ASTM F877-18a, ASTM F1807-2018

Plastic Fixtures:
ANSI Z124.1.2 (Except Sections 5.3, 6.1, 6.3), CSA B45.5-17/IAPMO Z124-17, IAPMO IGC 154-2018a, ASME A112.19.15-2012

Plastic Pipe\Fittings:
ASTM F1960-15, CSA B137.5-13, IAPMO IGC 319-2016 (Except Section 4.3), IAPMO IGC 109-2015, ASTM D2846-2017, ASTM F2159-2014, CSA B137.6-2013

Valves\Faucets:
AS/NZS 3718:2005 (Except Section 4.7), AS/NZS 3662:2005, ASME A112.18.1-2018/CSA B125.1-18 (Except Section 4.9, 5.4.3 and 5.13), IAPMO/ANSI Z1157-2014e1, EPA WaterSense High-Efficiency Lavatory Faucet Specification, Version 1.2 Dated 2007-10-01, EPA WaterSense Specification for Tank-Type Toilets, Version 1.1 Dated 2011-05-20, MSS SP-80, EPA WaterSense Specification for Showerheads, Version 1.1 Dated 2018-07-26, ASSE 1014-2005, ASSE 1016-2017/ASME A112.1016-2017/CSA B125.16-17, MSS SP-110-2010, AS/NZS 6400-2005, ICC A117.1-2008, ASSE 1019-2011, IAPMO IGC 312a-2018, CalGreen 2016, IGC 168-2012 (except ASSE 1010)

Virteous China Fixtures:
AS 1976-1992, AS 1756-1999, AS 3494-1997, AS/NZS 1730:1996, AS/NZS 3982:1996,
ASME A112.19.2-2018/ CSA B45.1-18, CSA B45.0-08 (for ceramic plumbing fixtures), CSA B45.1-08, EPA WaterSense High Efficiency Flushing Urinal Specification, Version 1.2 Dated 2009-08-14

Water Closets:
AS 1172.1-2005, AS 1172.2-1999, ASME A112.19.14-2013, IAPMO PS 50-2010 / CSA B125.3, LADWP-2005, MaP Performance Test


Return to List