RECOGNIZED LABS
For More Information and Test to Standards on the following
labs, download the .pdf copy by clicking here.
INTERTEK (GUANGZHOU)
1-8TH FLOOR, BLOCK E2, 11 CAI
PIN ROAD, SCIENCE CITY,
GUANGZHOU ECONOMIC DEVELOPMENT
GUANGZHOU, 510730
CHINA
Contact: BAUD QIU
Phone: 86-20-8213-9688
Fax: 86-20-3205-7538
|
|
Lab #: 0000081
Expires: 6/30/2013
Number of Employees: 200
|
|
Tests to Standards:
|
APPLIANCES: ASSE 1008-2006, IGC 226-2006a, ASSE 1023-1979
BACKFLOW PREVENTERS: ASSE 1024-2004, ASME A112.18.3-2002 (R08), CSA B125.3-2003, CSA B64-2001
BALLCOCKS/FLUSHOMETERS: ASME A112.19.5-2005, ASME A112.19.10-2003 (R08), ASSE 1002-2008, ASSE 1037-1990
BATHROOM ACCESSORIES: IAPMO IGC 186-2004a
LOW LEAD: NSF 372-10
METAL PIPE/FITTINGS: ASME A112.18.2-2005/ CSA B125.2-05, ASME B16.22-2001, ASTM A 888-2009, CSA B70-2006, CSA B602-2005, ASTM-B75-2002 (Except sections 6, 15.2), ASTM-B88-2009 (Except sections 6, 10.1), ASTM-B280-2008 (Except sections 6, 11.0), ASTM-B306-2009(Except sections 6, 9.2), ASTM-B837-2009 (Except sections 6, 10.1), ASTM C 564-09A, ASTM C 1277-09a, ASTM C 1540-09a, ASME A112.6.3-2001, SAE J1670-2005, CAN/CGSB 12.1 (M90), ASTM B687-1999 (R05) e1, ASME A112.21.3M-1985 (R2001), ASTM A74-2009
METAL FIXTURES: ASME A112.19.3-2008/ CSA B45.4-08, CSA B45.3-2002 (R08), ASME-A112.19.1-08/ CSA B45.2-08, ASME A112.19.4M-98, ASME A112.6.2-2000 (R2004)
NON-METALLIC PIPE & FITTINGS: ASME A112.18.6-2003, ASTM F409-2002 (R08)
NON VITREOUS CHINA FIXTURES: ASME A112.19.2-2008, ASME A112.19.5-2005
PHYSICAL/STRUCTURAL: ANSI Z97.1-2004E, 16 CFR PART 1201
PLASTIC CELL CLASS TESTING: ASTM D1784-2008, ASTM D4101-2010, ASTM D3965-2005, ASTM D3350-2008 PLASTIC FIXTURES: ANSI Z124.1.2-2005, ANSI Z124.3-2005, ANSI Z124.4-2006, ANSI Z124.5-2006, ANSI Z124.6-2007, ANSI Z124.7- 1997, ANSI Z124.8-1990, ANSI Z124.9-2004, ASME A112.19.7-2006 (CSA B45.10), CSA B45.5, IAPMO IGC 172-2010(CSA B45.11), IAPMO IGC 154-2009, IAPMO PS 99-2007, ASME A112.19.15-2005
PLASTIC PIPE/FITTINGS: CSA B79-2009, IAPMO IGC 224-2009, ASTM F877-2007, ASTM-F876-2010, ASTM D2241-2009, ASTM D1785-2006, ASTM D2661-2008, D2665-2009, D3035-2010, ASTM F1281-2007, ASTM F1282-2010, ASTM F1807-2010, ASTM F1974-2009,ASTM F2159-2005, ASTM F2389-2010,ASSE 1061-2011, CSA B137.1-09, CSA-B137.2-09 , CSA-B137.3-09 , CSA-B137.4-2009, CSA B137.4.1-09, CSA B137.5-2009, CSA B137.6-09 , CSA B137.8-09 , CSA B137.9-09 , CSA B137.10-09, CSA B137.11-09 , CSA B137.12-09, IAPMO IGC 223-2007, ASTM D2466-2006
POOL/SPA COMPONENTS/FITTINGS: ASME A112.19.7-2006(CSA B45.10), ASME A112.19.8b-2009, IAPMO PS 33-2011
TOXICITY TESTING: NSF 61-2010a(Water extraction only),NSF 61-4, NSF 61-8 “Only Water Extraction”, AB 1953-2008,
VACUUM BREAKERS: ASSE 1001-2008, ASSE 1011-2004
VALVES/FAUCETS: ASME A112.18.1-2011/ CSA B125.1-11 (Less Section 2.1 Toxicity Evaluation but include Water Extraction), ASSE 1014-2005, ASSE 1016-2005, ASSE 1019-2004, IAPMO IGC 157-2010, IAPMO PS 50-2010 , CSA-B125.3-05, ANSI A117.1-2003, EPA High-Efficiency Lavatory Faucets-2007, IAPMO IGC 267-2010, MSS-SP-80-2008, EPA High Efficiency Shower Heads 2010, NSF 14-2009
VITREOUS CHINA FIXTURES: ASME A112.19.2-2008/ CSA B45.1-08
WATER CLOSET: ASME A112.19.14-2006,ASME A112.4.2-2009, ASME A112.6.2-200 (R2004), EPA High Efficiency Toilet -2007, LADWP SPS-2005, EPA High Efficiency Flushing Urinal-2009
|

|