NSF INTERNATIONAL
789 DIXBORO ROAD
ANN ARBOR, MI 48105
United States
Contact: LYNN TUREK-REYNOLDS

Phone: 734 769-8010
Fax: 734-827-7182
   Lab #: 0000057
Expires: 5/31/2013
Number of Employees: 260

Tests to Standards:
BACKFLOW PREVENTERS:
ASSE 1012-2002 (CSA,CAN/CSA-B64.8-94), 1013-2005 (CSA,CAN/CSA-B64.4-94), 1015-2005, 1019-2004, 1020-2004 (CSA, B45.2-94), 1022-2003, 1024-2004 (CSA, CAN/CSA-B64.3-94), 1032-2004, 1035-2008 (CSA,CAN/CSA-B64.7-94), 1047-2005, 1048-2005, 1052-2004

BALLCOCKS & FLUSHOMETERS & FLUSH VALVES:
ASSE 1002-2008, ASSE 1037-1990, ASME A112.19.5-2005

CEMENTS, SOLDERS & JOINT COMPOUNDS:
ANSI/NSF 14-2007, ANSI/NSF 61-2008, ASTM D 2235-2004, D 2564-2004e1, D 3138-2004, D 3139-1998 (R05), ASTM F 493-2004

MFD. HOUSING/R.V. COMPONENTS:
ANSI/NSF 24- 1988(R06), ANSI Z 124.1.2-2005, ANSI Z 124.3-2005, ANSI Z 124.4-2006, ANSI Z 124.5-2006, ANSI Z 124.6-2007, ANSI Z 124.7-1997, CSA B45.5-2002 (R08), ANSI Z 124.8-1990, ANSI Z 124.9-2004, CSA B45.6-2002 (R08), CSA B45.7-2002 (R08), IAPMO TS 1-2005

METAL FIXTURES:
ASME A112.1.2-2004, ASME A112.3.1-1993, ASME A112.18.1-2005, ASME A112.18.6-2009, ASME A112.18.7-1999(R2004), ASME A112.19.1 -2008(CSA, B45.2-2002(R08)), ASME A112.19.2-2008, ASME A112.19.3 (CSA, B45.4-2002(R08)), ASME A 112.19.7-2006 (CSA, CAN/CSA-B45S1-88), ASME A112.19.10-2003(R08), ASME A112.21.1, ASME A112.21.3M-1985(R2001), ASME A112.36.2-1991(R08), CSA B45.1-2002(R08), CSA B45.2-2002(R08), CSA B45.3-2002(R08), CSA B45.4-2002(R08), IGC 195-2009

METAL PIPE & FITTINGS:
ASME A112.18.2-2005, ASME A112.6.3-2001, ASME B16.22-2001, ASTM B 280-2008, B 306-2002, C 1277-2008, F 1807-2008, F 2080-2008, PS 117-2008, ASTM B687-1999(R05)e1

NONMETALLIC PIPE/FITTINGS:
ASTM C 1460-2008

PLASTIC CELL CLASS TESTING:
ASTM C 564-2003a(except sec. 9.7(ozone exposure)),ASTM D 1248-1984, ASTM D 1784-2008, ASTM D 3350-2008, ASTM D 3965-2005, ASTM D 4101-2008

PLASTIC FIXTURES:
ASSE 1010-2004, ASSE 1014-2005, ASSE 1050-2002, ASSE 1051-2002, CSA B45.5-2002 (R08), IAPMO PS 99-2007

PLASTIC PIPE/FITTINGS:
ASTM D 1527-1999, D 2104-2003(CSA, B137.3-93), D 1785-2006, D 2235-2004, D 2239-2003, D 2241-2005, D 2447-2003(CSA, B137.3-93), D 2464-2006, D 2466-2006, D 2467-2006, D 2513-2008, D 2609-2002, D 2661-2008(CSA, CAN/CSA-B181.1-M90), D 2665-2009(CSA, CAN/CSA-B181.2-M90), D 2672-1196a(R2003), D 2683-1970, D 2729-2003, D 2737-2003, D 2751-2005, D 2846-2009(CSA, B137.6-M1983), D 2996-2001,D 3034-2008, D 3035-2003a, D 3138-2004, D 3212-1996a, D 3261-1997, D 3309-2002, F 409-2002(R08), F 437-2006, F 438-2004, F 439-2006, F 441-1999, F 442-1999, F 480-2006b, F 876-2008a, F 877-2007(CSA, CAN/CSA-B137.5-M89), F 1055-1998e1, F1216-2007b, F 1281-2007(CSA, CAN/CSA-B137.9-M91), F 1282-2006(CSA, CAN/CSA-B137.10-M91), F 1335-2004, F 1336-1999(R03),F 1412-2009, F 1866-2005, F 1960-2004, F 1970-2005, F 1974-2004, F 1986-2001, F 2389-2007, AWWA C 900-1997, C 901-1997, C 906-1999, C 907-2004, CSA B 137.1-2002, CSA B 137.2-2002, CSA B 137.3-2002, CSA B 137.4-2002, CSA B 137.5-2005, CSA B 137.6-2002, CSA B 137.7-2002, CSA B 137.8-2002, CSA B 137.9-2005, CSA B 137.10-2002, CSA B 137.11-2002, CSA B 181.1-2002, CSA B 181.2-2002, NSF 14-2007, IAPMO IGC 109-2009, IGC 210-2005a, IGC 223-2007, PS 33-2009c, ASTM A 1045-2008, IAPMO IGC 277-2010, ASTM F1488-2009

POOL SPA COMPONENTS & SYSTEMS: ( DE Filters, Sand Filters, Multi-port Valves, Cartridge Filters, Centrifugal pumps, Multiport vavles, Recessed automatic surface skimmers, Adjustable output chemical feeders, Flow through chemical feeders, Process equipment-includes: Ozone generators, UV-Hydrogen Peroxide disinfection systems, In-line electrolytic chlorine/bromine generation, Brine-type electrolytic chlorine/bromine generation, and Copper/silver in generation disinfection systems.), IAPMO PS 33-2009c flexible spa hose , IAPMO SPS-4 -2009 suction fittings

SEPTIC SYSTEMS:
CSA B 66-2005,B 481-2007, IAPMO PS 1-2007, PS 63-2005, ASME A112.14.3-2000, ASME A112.14.4-2001, PDI-G101-1998, IAPMO Z1000-2007

SHOWER PAN LINERS:
ANSI Z 124.2-2005 (CSA, B45.5-94), ANSI Z 124.8-1990, ASTM D4551-1996(R08)e1

TOXICITY:
ANSI/NSF 14-2007,ANSI/NSF 60-2009, ANSI/NSF 61-9-2008

VACUUM BREAKERS:
ASSE 1001-2008, ASSE 1011-2004(CSA, CAN/CSA-B64.2.1-94, B64.2.2-94, B64.1.2-94), 1060-2006, CSA B64-2001, ASSE 1056-2001

VALVES & FAUCETS:
ASME A112.18.1-2005 (CSA, CAN/CSA-B70-M91),ASME A112.19.2-2008, ASSE 1003-2001(up to 1' only), 1016-2005, CSA B 125-2005, B 356-2000 (up to 1' only), LADWP SPS Ultra Low Flush Supplement to ASME A112.19.2-2008, IGC 168-2001, IAPMO PS 87-1995, IAPMO PS 101-1997

VITREOUS CHINA FIXTURES:
ASME A112.19.2-2008, CSA B 45.2-2002(R08)

WATER CLOSETS:
ANSI Z 124.4-2006, ANSI Z 124.9-2004 (CSA B 45.2-2002(R08), ASME A112.14.2-2009

WATER FILTERS/CONDITIONERS:
AANSI/NSF 53-2007a, IAPMO PS 65-2002

WATER HEATERS:
ASME A112.18.1-2005