IAPMO R&T
IAPMO R&T

 

RECOGNIZED LABS

For More Information and Test to Standards on the following labs, download the .pdf copy by clicking here.

 

NSF INTERNATIONAL
789 DIXBORO ROAD
ANN ARBOR, MI 48105
United States
Contact: LYNN TUREK-REYNOLDS

Phone: 734 769-8010
Fax: 734-827-7182
   Lab #: 0000057
Expires: 5/31/2019
Number of Employees: 260

Tests to Standards:
BACKFLOW PREVENTERS:
ASSE 1012-2009 (CSA-B64.8-11), 1013-2011 (CSA-B64.4-11), ASSE 1015-2011, ASSE 1019-2011, ASSE 1020-2004 (CSA B64.1.2-11), ASSE 1022-2003, 1024-2004 (CSA-B64.3-11), ASSE 1032-2004, ASSE 1035-2008 (CSA B64.7-11), ASSE 1047-2011, ASSE 1048-2011, ASSE 1052-2004

BALLCOCKS & FLUSHOMETERS & FLUSH VALVES:
ASSE 1002-2015/ ASME A112.1002-2015/ CSA B125.12-15, ASSE 1037-2015/ ASME A112.1037-2015/ CSA B125.37-2015, ASME A112.19.5-2017/ CSA B45.15-17

CEMENTS, SOLDERS & JOINT COMPOUNDS:
ANSI/NSF 14-2007, ASTM D2235-2004(R2011), ASTM D2564-12, ASTM D3138-04, ASTM D3139-1998(R2011), ASTM F493-14

MFD. HOUSING/R.V. COMPONENTS:
ANSI/NSF 24- 1988(R06), CSA B45.5-17/ IAPMO Z124-2017, ANSI Z 124.3-2005, ANSI Z 124.4-2006, ANSI Z 124.5-2006, ANSI Z 124.6-2007, ANSI Z 124.7-1997, CSA B45.5-2002 (R08), ANSI Z 124.8-1990, ANSI Z 124.9-2004, CSA B45.6-2002 (R08), CSA B45.7-2002 (R08), IAPMO TS 1-2005, IAPMO TS 2-2015

METAL FIXTURES:
ASME A112.1.2-2004, ASME A112.3.1-1993, ASME A112.18.1-2012/ CSA B125.1-12, ASME A112.18.6-2017/ CSA B125.6-17, ASME A112.19.1 -2013/CSA B45.2-13, ASME A112.19.2-2013/CSA B45.1-13, ASME A112.19.3-2017/ CSA B45.4-17, ASME A 112.19.7-2006 (CSA, CAN/CSA-B45S1-88), ASME A112.19.10-2003(R08), ASME A112.21.1, ASME A112.21.3M-1985(R2001), ASME A112.36.2-1991(R08), CSA B45.1-2002(R08), CSA B45.2-2002(R08), CSA B45.3-2002(R08), CSA B45.4-2002(R08), IGC 195-2009

METAL PIPE & FITTINGS:
ASME A112.18.2-2005, ASME A112.6.3-2001, ASME B16.22-2001, ASTM B 280-2008, B 306-2002, C 1277-2008, F 1807-2008, F 2080-2008, PS 117-2008, ASTM B687-1999(R05)e1, ASSE 1061-2006, ASTM C1173-2010e1(R2014), CSA B602-2010 (Except section 5.14 and 5.17)

NONMETALLIC PIPE/FITTINGS:
ASTM C 1460-2008

PLASTIC CELL CLASS TESTING:
ASTM C 564-2003a(except sec. 9.7(ozone exposure)),ASTM D 1248-1984, ASTM D 1784-2008, ASTM D 3350-2008, ASTM D 3965-2005, ASTM D 4101-2008

PLASTIC FIXTURES:
ASSE 1010-2004, ASSE 1014-2005, ASSE 1050-2002, ASSE 1051-2002, CSA B45.5-2002 (R08), IAPMO PS 99-2007

PLASTIC PIPE/FITTINGS:
ASTM D 1785-2006, ASTM D2235-2004(R2011), D 2239-2003, D 2241-2005, D 2447-2003(CSA, B137.3-93), D 2464-2006, D 2466-2006, D 2467-2006, D 2513-2008, D 2609-2002, ASTM D2661-14 (CSA-B181.1-11), D 2665-2009(CSA, CAN/CSA-B181.2-M90), D 2672-1196a(R2003), D 2683-1970, D 2729-2003, D 2737-2003, D 2751-2005, D 2846-2009(CSA, B137.6-M1983), D 2996-2001,D 3034-2008, D 3035-2003a, ASTM D3138-2004, D 3212-1996a, D 3261-1997, D 3309-2002, F 409-2002(R08), F 437-2006, F 438-2004, F 439-2006, F 441-1999, F 442-1999, F 480-2006b, F 876-2008a, F 877-2011a(CSA, CAN/CSA-B137.5-M89), F 1055-1998e1, F1216-2016, F 1281-2007(CSA, CAN/CSA-B137.9-M91), F 1282-2006(CSA, CAN/CSA-B137.10-M91), F 1335-2004, F 1336-1999(R03),F 1412-2009, F 1866-2005, F 1960-2004, F 1970-2005, F 1974-2004, F 1986-2001, F 2389-2017a, AWWA C 900-1997, C 901-1997, C 906-1999, C 907-2004, CSA B 137.1-2002, CSA B 137.2-2002, CSA B 137.3-2002, CSA B 137.4-2002, CSA B 137.5-2005, CSA B 137.6-2002, CSA B 137.7-2002, CSA B 137.8-2002, CSA B 137.9-2005, CSA B 137.10-2002, CSA B 137.11-2002, CSA B 181.1-2002, CSA B 181.2-2002, NSF 14-2007, IAPMO IGC 109-2009, IGC 210-2005a, IGC 223-2007, PS 33-2009c, ASTM A 1045-2008, IAPMO IGC 277-2010, ASTM F1488-2009, ASTM F1807-2008, ASTM F2023-13, AWWA C904-06, IGC 334-2016

POOL SPA COMPONENTS & SYSTEMS: ( DE Filters, Sand Filters, Multi-port Valves, Cartridge Filters, Centrifugal pumps, Multiport vavles, Recessed automatic surface skimmers, Adjustable output chemical feeders, Flow through chemical feeders, Process equipment-includes: Ozone generators, UV-Hydrogen Peroxide disinfection systems, In-line electrolytic chlorine/bromine generation, Brine-type electrolytic chlorine/bromine generation, and Copper/silver in generation disinfection systems.), IAPMO PS 33-2009c flexible spa hose , IAPMO SPS-4 -2009 suction fittings, IAPMO/ ANSI Z1033-2013, IAPMO PS 3-93, IAPMO PS 5-2006

SEPTIC SYSTEMS:
CSA B 66-2005,B 481-2007, IAPMO PS 1-2007, PS 63-2005, ASME A112.14.3-2000, ASME A112.14.4-2001, PDI-G101-1998, IAPMO Z1000-2007, IAPMO IGC 273-2009

SHOWER PAN LINERS:
ANSI Z 124.2-2005 (CSA, B45.5-94), ANSI Z 124.8-1990, ASTM D4551-1996(R08)e1

TOXICITY:
ANSI/NSF 14-2007,ANSI/NSF 60-2009, NSF 61-2016, AS 2345-2006, ANSI/ NSF 372-2011

VACUUM BREAKERS:
ASSE 1001-2008, ASSE 1011-2004(CSA, CAN/CSA-B64.2.1-94, B64.2.2-94, B64.1.2-94), 1060-2006, CSA B64-2001, ASSE 1056-2013

VALVES & FAUCETS:
ASME A112.18.1-2012/ CSA B125.1-12, (CSA, CAN/CSA-B70-M91), ASME A112.19.2-2013/CSA B45.1-13, ASSE 1003-2001(up to 1' only), 1016-2005, CSA B 125-2005, B 356-2000 (up to 1' only), LADWP SPS Ultra Low Flush Supplement to ASME A112.19.2-2013, IGC 168-2001, IAPMO PS 87-1995, IAPMO PS 101-1997, ANSI/ ISEA Z358.1-2009, AS 4775-2007

VITREOUS CHINA FIXTURES:
ASME A112.19.2-2013/CSA B45.1-13, CSA B 45.2-2002(R08)

WATER CLOSETS:
ANSI Z 124.4-2006, ANSI Z 124.9-2004 (CSA B 45.2-2002(R08), ASME A112.14.2-2009

WATER FILTERS/CONDITIONERS:
NSF/ANSI 53-2014, IAPMO PS 65-2002

WATER HEATERS:
ASME A112.18.1-2012/ CSA B125.1-12

Return to List