RECOGNIZED LABS
For More Information and Test to Standards on the following
labs, download the .pdf copy by clicking here.
NSF INTERNATIONAL
789 DIXBORO ROAD
ANN ARBOR, MI 48105
United States
Contact: LYNN TUREK-REYNOLDS
Phone: 734 769-8010
Fax: 734-827-7182
|
|
Lab #: 0000057
Expires: 5/31/2013
Number of Employees: 260
|
|
Tests to Standards:
|
BACKFLOW PREVENTERS: ASSE 1012-2002 (CSA,CAN/CSA-B64.8-94), 1013-2005 (CSA,CAN/CSA-B64.4-94), 1015-2005, 1019-2004, 1020-2004 (CSA, B45.2-94), 1022-2003, 1024-2004 (CSA, CAN/CSA-B64.3-94), 1032-2004, 1035-2008 (CSA,CAN/CSA-B64.7-94), 1047-2005, 1048-2005, 1052-2004
BALLCOCKS & FLUSHOMETERS & FLUSH VALVES: ASSE 1002-2008, ASSE 1037-1990, ASME A112.19.5-2005
CEMENTS, SOLDERS & JOINT COMPOUNDS: ANSI/NSF 14-2007, ANSI/NSF 61-2008, ASTM D 2235-2004, D 2564-2004e1, D 3138-2004, D 3139-1998 (R05), ASTM F 493-2004
MFD. HOUSING/R.V. COMPONENTS: ANSI/NSF 24- 1988(R06), ANSI Z 124.1.2-2005, ANSI Z 124.3-2005, ANSI Z 124.4-2006, ANSI Z 124.5-2006, ANSI Z 124.6-2007, ANSI Z 124.7-1997, CSA B45.5-2002 (R08), ANSI Z 124.8-1990, ANSI Z 124.9-2004, CSA B45.6-2002 (R08), CSA B45.7-2002 (R08), IAPMO TS 1-2005
METAL FIXTURES: ASME A112.1.2-2004, ASME A112.3.1-1993, ASME A112.18.1-2005, ASME A112.18.6-2009, ASME A112.18.7-1999(R2004), ASME A112.19.1 -2008(CSA, B45.2-2002(R08)), ASME A112.19.2-2008, ASME A112.19.3 (CSA, B45.4-2002(R08)), ASME A 112.19.7-2006 (CSA, CAN/CSA-B45S1-88), ASME A112.19.10-2003(R08), ASME A112.21.1, ASME A112.21.3M-1985(R2001), ASME A112.36.2-1991(R08), CSA B45.1-2002(R08), CSA B45.2-2002(R08), CSA B45.3-2002(R08), CSA B45.4-2002(R08), IGC 195-2009
METAL PIPE & FITTINGS: ASME A112.18.2-2005, ASME A112.6.3-2001, ASME B16.22-2001, ASTM B 280-2008, B 306-2002, C 1277-2008, F 1807-2008, F 2080-2008, PS 117-2008, ASTM B687-1999(R05)e1
NONMETALLIC PIPE/FITTINGS: ASTM C 1460-2008
PLASTIC CELL CLASS TESTING: ASTM C 564-2003a(except sec. 9.7(ozone exposure)),ASTM D 1248-1984, ASTM D 1784-2008, ASTM D 3350-2008, ASTM D 3965-2005, ASTM D 4101-2008
PLASTIC FIXTURES: ASSE 1010-2004, ASSE 1014-2005, ASSE 1050-2002, ASSE 1051-2002, CSA B45.5-2002 (R08), IAPMO PS 99-2007
PLASTIC PIPE/FITTINGS: ASTM D 1527-1999, D 2104-2003(CSA, B137.3-93), D 1785-2006, D 2235-2004, D 2239-2003, D 2241-2005, D 2447-2003(CSA, B137.3-93), D 2464-2006, D 2466-2006, D 2467-2006, D 2513-2008, D 2609-2002, D 2661-2008(CSA, CAN/CSA-B181.1-M90), D 2665-2009(CSA, CAN/CSA-B181.2-M90), D 2672-1196a(R2003), D 2683-1970, D 2729-2003, D 2737-2003, D 2751-2005, D 2846-2009(CSA, B137.6-M1983), D 2996-2001,D 3034-2008, D 3035-2003a, D 3138-2004, D 3212-1996a, D 3261-1997, D 3309-2002, F 409-2002(R08), F 437-2006, F 438-2004, F 439-2006, F 441-1999, F 442-1999, F 480-2006b, F 876-2008a, F 877-2007(CSA, CAN/CSA-B137.5-M89), F 1055-1998e1, F1216-2007b, F 1281-2007(CSA, CAN/CSA-B137.9-M91), F 1282-2006(CSA, CAN/CSA-B137.10-M91), F 1335-2004, F 1336-1999(R03),F 1412-2009, F 1866-2005, F 1960-2004, F 1970-2005, F 1974-2004, F 1986-2001, F 2389-2007, AWWA C 900-1997, C 901-1997, C 906-1999, C 907-2004, CSA B 137.1-2002, CSA B 137.2-2002, CSA B 137.3-2002, CSA B 137.4-2002, CSA B 137.5-2005, CSA B 137.6-2002, CSA B 137.7-2002, CSA B 137.8-2002, CSA B 137.9-2005, CSA B 137.10-2002, CSA B 137.11-2002, CSA B 181.1-2002, CSA B 181.2-2002, NSF 14-2007, IAPMO IGC 109-2009, IGC 210-2005a, IGC 223-2007, PS 33-2009c, ASTM A 1045-2008, IAPMO IGC 277-2010, ASTM F1488-2009
POOL SPA COMPONENTS & SYSTEMS: ( DE Filters, Sand Filters, Multi-port Valves, Cartridge Filters, Centrifugal pumps, Multiport vavles, Recessed automatic surface skimmers, Adjustable output chemical feeders, Flow through chemical feeders, Process equipment-includes: Ozone generators, UV-Hydrogen Peroxide disinfection systems, In-line electrolytic chlorine/bromine generation, Brine-type electrolytic chlorine/bromine generation, and Copper/silver in generation disinfection systems.), IAPMO PS 33-2009c flexible spa hose , IAPMO SPS-4 -2009 suction fittings
SEPTIC SYSTEMS: CSA B 66-2005,B 481-2007, IAPMO PS 1-2007, PS 63-2005, ASME A112.14.3-2000, ASME A112.14.4-2001, PDI-G101-1998, IAPMO Z1000-2007
SHOWER PAN LINERS: ANSI Z 124.2-2005 (CSA, B45.5-94), ANSI Z 124.8-1990, ASTM D4551-1996(R08)e1
TOXICITY: ANSI/NSF 14-2007,ANSI/NSF 60-2009, ANSI/NSF 61-9-2008
VACUUM BREAKERS: ASSE 1001-2008, ASSE 1011-2004(CSA, CAN/CSA-B64.2.1-94, B64.2.2-94, B64.1.2-94), 1060-2006, CSA B64-2001, ASSE 1056-2001
VALVES & FAUCETS: ASME A112.18.1-2005 (CSA, CAN/CSA-B70-M91),ASME A112.19.2-2008, ASSE 1003-2001(up to 1' only), 1016-2005, CSA B 125-2005, B 356-2000 (up to 1' only), LADWP SPS Ultra Low Flush Supplement to ASME A112.19.2-2008, IGC 168-2001, IAPMO PS 87-1995, IAPMO PS 101-1997
VITREOUS CHINA FIXTURES: ASME A112.19.2-2008, CSA B 45.2-2002(R08)
WATER CLOSETS: ANSI Z 124.4-2006, ANSI Z 124.9-2004 (CSA B 45.2-2002(R08), ASME A112.14.2-2009
WATER FILTERS/CONDITIONERS: AANSI/NSF 53-2007a, IAPMO PS 65-2002
WATER HEATERS: ASME A112.18.1-2005
|

|
© 2013 - IAPMO Research and Testing, All Rights Reserved
|