RECOGNIZED LABS
For More Information and Test to Standards on the following
labs, download the .pdf copy by clicking here.
CRT LABORATORIES (CALIFORNIA RESIN TESTING)
1680 N MAIN STREET
ORANGE, CA 92867
United States
Contact: KEN LE JUENE
Phone: 714 283-2032
Fax: 714 283-1365
|
|
Lab #: 0000037
Expires: 6/30/2013
Number of Employees: 4
|
|
Tests to Standards:
|
BACKFLOW PREVENTERS ASME A112.14.1-2003 (R08)
CEMENTS/SOLDER/JOINT COMPOUNDS: ASTM B 32-2008(sections 8.1, 8.1.1, 8.1.2, 8.2, 8.3.1, 8.3.2, 13.1, 13.1.1, 13.1.2, 13.1.3, 13.3.1, 13.3.2, 13.3.3, 13.3.4, 13.3.5), B 813-200e1, D 2235-2004, D 2564-2004e1, D 2672-1996a (R2003), D 2855-96 (R2002), D 3122-1995 (R2002), D 3212-1996a, F 656-2008
ELECTRICAL: UL 651-1995
MANUFACTURED HOUSING/RV COMPONENTS: IAPMO PS 42-1996, PS 54-2006, PS 94-2008, PS 95-2001, PS 64 -2007a(except 4.1.1),CSA B272-93 (R008)
METAL FIXTURES: ASME A112.6.4-2003 (R08), ASME A112.18.6-2009, ASME A 112.6.3-2001, ASME A112.6.7-2001, IAPMO PS 9-2006,
METAL PIPE/FITTINGS: ASME A112.18.6-2003, ASTM C 1173-2008 (except section 9.1.4), ASTM F 1807-2008 (except 5), ASTM F 2306-2007 (except section 7.8), ASME A112.18.2-2011/ CSA B125.2-11 (except sections: 5.2 & 5.4), PS 120-2004 (except 4.1), ASTM C 1053-2000 (R2005), ASTM C 1460-2008, ASTM F 1948-2005.
PIPE WRAP TAPE/COATINGS: IAPMO PS 37-1990 (except dielectric breakdown, High Humidity Insulation Resistance)
PLASTIC CELL CLASS TESTING: Fingerprinting material using infrared and differential scanner ASTM D 1248-1984, D 1784-2008, D 3350-2008, D 3965-2005, D 4101-2008 (except section 13.1.7), ASTM C 564-2003a (except 9.7)
PLASTIC FIXTURES: ANSI Z124.5-2006, IAPMO PS 94-2008, PS 90-2006 (except 4.1.2), ANSI Z 124.1.2-2005 (except 5.1, 5.3, 6.2), ANSI Z 124.3-2005 (except 5.1, 5.3, 6.2), ANSI Z124.4 -2006(except 5.1, 5.3, 6.2), ANSI Z124.6 -2007(except 5.1, 5.3, 6.2), ANSI Z124.8-1990 (except 5.1, 5.3, 6.2), ANSI A112.6.4-2003(R08) , ASME A112.6.3-2001 , ASME A112.18.6-2009
PIPE WRAP TAPES\COATINGS: AWWA C210-2003, AWWA C213-2007, IGC 189-2008
PLASTIC PIPE/FITTINGS: ASME A112.18.6-2009, ASTM D 1527-1999, D 1785-2006, D 2104-2003, D 2239-2003, D 2241-09, D 2466-2006, D 2467-2006, D 2468, D 2513-11, D 2661-11(CSA, CAN/CSA-B181.1-M90), D 2665-11(CSA, CAN/CSA-B181.1-M80), D 2680-2001 (R09), D 2729-11, D 2737-2003, D2751-2005, D 2846-2009, D 3034-2008(CSA, CAN/CSA-B182.2-M90), D 3212-07, D 3311-11, F 405-2005, F 409-2002 (R08), F 437-09, F 438-09, F 439-11, F 441-09, F 442-09, F 628-2008, F 667-2006, F 794-2003(R09), F 810-2007, F 876-11, F 877-11, F 891-2007, F 949-2003, F 1412-2009, F 1673-2004, F 2158-2008;ASME A112.18.2-2011/ CSA B125.2-11(except sections: 5.2 & 5.4), A112.14.1-2003(R08) ,A112.6.4-2003 (R08),A112.6.3-2001, IAPMO PS 33-2010, PS 51-1998, PS 90-2006 (except 4.1.2), PS 94-2008, AWWA C900-1997 (pipe sizes through 8"),IAPMO IGC 120-1998a, IAPMO IGC 224-2009, ASTM F 1924-2005, NSF 14-2007
POOL/SPA COMPONENTS/FITTINGS: IAPMO PS 33-2010, IAPMO IGC 158-2000
SEPTIC SYSTEMS: IAPMO/ANSI Z1000-2007, IAPMO IGC 219-2005, IAPMO IGC 262-2008, IAPMO PS 63-2005, IGC 276-2010
SHOWER PAN LINERS: ANSI A118.10-2008 (except M-4.1), ASTM D 4068-2001 (except 4.1),
VALVES/FAUCETS: ASSE 1016-2005, ASSE 1014-2005, ASME A112.18.2011/ CSA B12.5.1-11(except sections: 5.2, 5.3.6.2, 5.9.2.1, 4.9 Toxicity), (CSA, CAN/CSA-B70-M91)
|

|